Output power cable, Power load cable, RS-232, USB cable
USB cable
Manual
Yes
Not listed
Management card included
Not listed
No
Quick installation guide
Not listed
Yes
Weight & dimensions
Width
438 mm
85 mm
Depth
88 mm
505 mm
Height
630 mm
432 mm
Weight
27.6 kg
20.5 kg
Battery width
Not listed
59.4 cm
Battery depth
Not listed
74.9 cm
Battery height
Not listed
24.6 cm
Packaging data
Package width
88 mm
Not listed
Package depth
438 mm
Not listed
Package height
630 mm
Not listed
Package weight
34.8 kg
Not listed
Logistics data
Master (outer) case net weight
27.6 kg
Not listed
Harmonized System (HS) code
85078000
85078000
Master (outer) case width
600 mm
Not listed
Master (outer) case length
760 mm
Not listed
Master (outer) case height
240 mm
Not listed
Master (outer) case gross weight
34.8 kg
Not listed
Products per master (outer) case
1 pc(s)
Not listed
Total carbon footprint (kg of CO2e)
Not listed
1839.69
Sustainability
Sustainability compliance
Not listed
Yes
Sustainability certificates
Not listed
Green Premium
Other features
Nominal output voltage
Not listed
230 V
Nominal input voltage
Not listed
230 V
From the supplier's listing
Capacity
3,000VA
1,000VA
Power
3,000W
1,000W
Type
Online (double conversion)
Online (double conversion)
Waveform
Not listed
Pure sine wave
Form
Not listed
Rackmount
Outlets
Not listed
6 x IEC
Battery
Not listed
Lead acid
Extras
USB charging, Network card slot
Network card slot
UPS topology
Double-conversion (Online)
Double-conversion (Online)
Output power capacity
3 kVA
1 kVA
Input operation voltage (min)
110 V
220 V
Input operation voltage (max)
300 V
240 V
Input frequency
40/70 Hz
40/70 Hz
Output operation voltage (min)
220 V
50 V
Output operation voltage (max)
240 V
240 V
Crest factor
3:1
3:1
ECO mode
Yes
Yes
Noise level
50 dB
50 dB
AC outlet types
C13 coupler, C19 coupler
C13 coupler
Power plug
C20 coupler
C14 coupler
AC outlets quantity
9 AC outlet(s)
12 AC outlet(s)
Serial interface type
RS-232
RJ-45
Serial ports quantity
1
1
Battery technology
Sealed Lead Acid (VRLA)
Sealed Lead Acid (VRLA)
Battery voltage
72 V
48 V
Typical backup time at full load
2.96 min
8 min
Typical backup time at half load
10.1 min
21 min
Battery recharge time
3 h
3 h
Overview
True double-conversion – output power factor is 1 (maxium), which means all of the power supplied is being used for productive work and makes work the most efficient
Programmable power management outlets – users can easily and independently control load segments. During power failure, this feature enables users to extend battery time to mission-critical devices by shutting down noncritical devi
APC Smart-UPS On-Line, 1000VA/1000W, Tower, 230V, 6x C13 IEC outlets, SmartSlot, Extended runtime, W/O rail kit
This APC Smart-UPS is designed for IT professionals or network administrators to maintain business uptime and continuity. This 1000VA on-line tower UPS provides pure sine wave power and extended runtime to support critical electronics during power disruptions. It comes with 1x IEC 320